Page 15 - Forward Modeling of Fast Ion Diagnostic Signals in C-2W with Monte Carlo Simulations
P. 15
'(! ')
and 𝑃#! are almost equal for low 𝑇! ,-! = / 𝑛#𝑉012 ,%! ~0.2 − 0.4 𝑀𝑊,
𝑉012 ≈ 0.9 𝑚/ - volume of FRC, defined from magnetics
𝑛# ≈ 1034 𝑚&/, ,%! ≈ 100 − 150 𝑒𝑉/𝑚𝑠 - using Thomson scattering
,.( ,.
𝑃!,# ≈ $! %#$# &(%! ~ 0.25 − 0.35 𝑀𝑊, '"!
,.
𝑇.5. ≈ 2 𝑘𝑒𝑉 - total temperature from magnetics 𝜏!# ≈0.01%!%/'~6 −12𝑚𝑠
$!
Ø Additional e- heating could not be clearly proven from dynamic 𝑉6!)7 at 𝑻𝒆~𝟐𝟓𝟎 𝒆𝑽.
Ø Dedicated dynamic biasing experiments at high electron temperatures, ≈ 500 𝑒𝑉 Ø Fast 𝑉&'() to a high value, up to 3.7 kV
Presenter: Manjit Kaur 15