 An in situ deterministic calibration can be performed with large data ensembles
β€’ Vary 𝐡()* between shots such that one energy 𝐸" strikes different MCP channels on each shot, as in the plot
β€’ The 𝑖,- channel β€œsees” the energy 𝐸":
π‘žπ΅()*Ξ”π‘₯" + 8π‘š
β€’ Problem – requires at least as many shots as there are MCP channels (39), more when accounting for experimental error
β€’ Solution – machine learning (ML) driven calibration to get maximum leverage from minimal data
  𝐸" =
   Presenter: Gabriel Player
8