Diagnostic suite of the C-2U advanced beam-driven field-reversed configuration plasma experiment

Diagnostic suite of the C-2U advanced beam-driven field-reversed configuration plasma experiment

August 2016 | M. C. Thompson | Review of Scientific Instruments | Paper

The C-2U experiment at Tri Alpha Energy studies the evolution of field-reversed configuration (FRC) plasmas sustained by neutral beam injection. Data on the FRC plasma performance are provided by a comprehensive suite of diagnostics that includes magnetic sensors, interferometry, Thomson scattering, spectroscopy, bolometry, reflectometry, neutral particle analyzers, and fusion product detectors.

High sensitivity far infrared laser diagnostics for the C-2U advanced beam-driven field-reversed configuration plasmas

High sensitivity far infrared laser diagnostics for the C-2U advanced beam-driven field-reversed configuration plasmas

August 2016 | B. H. Deng | Review of Scientific Instruments | Paper

A high sensitivity multi-channel far infrared laser diagnostics with switchable interferometry and polarimetry operation modes for the advanced neutral beam-driven C-2U field-reversed configuration (FRC) plasmas is described. The interferometer achieved superior resolution of 1 ⇥ 1016 m 2 at >1.5 MHz bandwidth, illustrated by measurement of small amplitude high frequency fluctuations.

Jet outflow and open field line measurements on the C-2U advanced beam-driven field-reversed configuration plasma experiment

Jet outflow and open field line measurements on the C-2U advanced beam-driven field-reversed configuration plasma experiment

August 2016 | D. Sheftman | Review of Scientific Instruments | Paper

Knowledge and control of the axial outflow of plasma particles and energy along open-magnetic-field lines are of crucial importance to the stability and longevity of the advanced beam-driven field- reversed configuration plasma. An overview of the diagnostic methods used to perform measurements on the open field line plasma on C-2U is presented, including passive Doppler impurity spectroscopy, microwave interferometry, and triple Langmuir probe measurements.

Hanle effect as a magnetic diagnostics for field-reversed configuration plasmas

Hanle effect as a magnetic diagnostics for field-reversed configuration plasmas

August 2016 | D. K. Gupta | Review of Scientific Instruments | Paper

Hanle effect is presented as a low magnetic-field diagnostic for field-reversed configuration (FRC) plasmas. The non-perturbative technique is capable of measuring not only magnetic-field pro- file and direction but also field-null position and its shape.

End loss analyzer system for measurements of plasma flux at the C-2U divertor electrode

End loss analyzer system for measurements of plasma flux at the C-2U divertor electrode

August 2016 | M. E. Griswold | Review of Scientific Instruments | Paper

An end loss analyzer system consisting of electrostatic, gridded retarding-potential analyzers and pyroelectric crystal bolometers was developed to characterize the plasma loss along open field lines to the divertors of C-2U. The system measures the current and energy distribution of escaping ions as well as the total power flux to enable calculation of the energy lost per escaping electron/ion pair.